ADDED Requirements
Requirement: Owner alert on scan
When a scan of an sms_enabled tag is recorded, the system SHALL send an SMS to the tag owner. The message SHALL include the item type and name, the scan time, a maps link when a location was shared, and the tag page link.
Scenario: Alert with location
- WHEN a scan with coordinates is recorded on an enabled tag outside the throttle window
- THEN the owner receives an SMS with item type, name, time, maps link, and tag page link, and
alert_sent = trueis recorded
Scenario: Alert without location (first scan)
- WHEN a scan without coordinates is recorded on an enabled tag outside the throttle window
- THEN the owner receives an SMS noting the finder did not share a location
Requirement: sms_enabled disabled means no alerts
When a tag has sms_enabled = false, scans SHALL be recorded but no SMS SHALL be sent and alert_sent SHALL remain false.
Scenario: Informational tag scanned
- WHEN a scan is recorded on a tag with
sms_enabled = false - THEN no SMS is sent and
alert_sent = false
Requirement: Location-aware throttle
Within a 10-minute window since the last alerted scan of the same tag, the system SHALL send a new alert only if the new scan has a location more than 250 meters from the last alerted location. A scan at the same location SHALL be recorded without a new alert.
Scenario: Same location within window
- WHEN a second scan of the same tag arrives within 10 minutes at the same location
- THEN the scan is recorded and no SMS is sent
Scenario: Moved more than 250 m within window
- WHEN a second scan of the same tag arrives within 10 minutes more than 250 m from the last alerted location
- THEN a new SMS is sent
Scenario: After the window
- WHEN a scan arrives more than 10 minutes after the last alert for the tag
- THEN an SMS is sent regardless of distance
Requirement: Swappable SMS sender
SMS sending SHALL go through an abstraction so that automated tests and development never send real SMS. With no SMS credentials configured, the app SHALL use a logging sender.
Scenario: No credentials in dev
- WHEN SMS credentials are not configured
- THEN sending an alert logs the message instead of calling the provider
Requirement: International number format
Phone numbers SHALL be normalised to international format without a leading + or leading zero before sending (e.g. +61423274487 or 0432374487 → 61423274487).
Scenario: Number normalisation
- WHEN an owner or finder number is stored in any local format