@license MIT License
|
|
|
|
Copyright (c) 2022 lewis he
|
|
|
|
Permission is hereby granted, free of charge, to any person obtaining a copy
|
|
of this software and associated documentation files (the "Software"), to deal
|
|
in the Software without restriction, including without limitation the rights
|
|
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
copies of the Software, and to permit persons to whom the Software is
|
|
furnished to do so, subject to the following conditions:
|
|
|
|
The above copyright notice and this permission notice shall be included in all
|
|
copies or substantial portions of the Software.
|
|
|
|
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
|
|
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
|
|
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
|
|
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
|
|
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
|
|
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
|
|
SOFTWARE.
|
|
|
|
@file AXP2101_Interrupt.py
|
|
@author Lewis He (lewishe@outlook.com)
|
|
@date 2022-10-20
|
|
|
|
'''
|
|
from AXP2101 import *
|
|
import time
|
|
|
|
SDA = None
|
|
SCL = None
|
|
I2CBUS = None
|
|
|
|
if implementation.name == 'micropython':
|
|
from machine import Pin, I2C
|
|
SDA = 21
|
|
SCL = 22
|
|
IRQ = 35
|
|
I2CBUS = I2C(scl=Pin(SCL), sda=Pin(SDA))
|
|
if implementation.name == 'circuitpython':
|
|
import digitalio
|
|
import board
|
|
import busio
|
|
SDA = board.IO42
|
|
SCL = board.IO41
|
|
IRQ = board.IO6
|
|
I2CBUS = busio.I2C(SCL, SDA)
|
|
|
|
irq = None
|
|
pmu_flag = False
|
|
|
|
|
|
def __callback(args):
|
|
global pmu_flag
|
|
pmu_flag = True
|
|
|
|
|
|
PMU = AXP2101(I2CBUS, addr=AXP2101_SLAVE_ADDRESS)
|
|
print('getID:%s' % hex(PMU.getChipID()))
|
|
|
|
PMU.disableIRQ(PMU.XPOWERS_AXP2101_ALL_IRQ)
|
|
# Clear all interrupt flags
|
|
PMU.clearIrqStatus()
|
|
PMU.printIntRegister()
|
|
|
|
PMU.enableIRQ(PMU.XPOWERS_AXP2101_PKEY_SHORT_IRQ |
|
|
PMU.XPOWERS_AXP2101_PKEY_NEGATIVE_IRQ)
|
|
# Print AXP2101 interrupt control register
|
|
PMU.printIntRegister()
|
|
|
|
# PMU.enableIRQ(
|
|
# PMU.XPOWERS_AXP2101_BAT_INSERT_IRQ | PMU.XPOWERS_AXP2101_BAT_REMOVE_IRQ | # BATTERY
|
|
# PMU.XPOWERS_AXP2101_VBUS_INSERT_IRQ | PMU.XPOWERS_AXP2101_VBUS_REMOVE_IRQ | # VBUS
|
|
# PMU.XPOWERS_AXP2101_PKEY_SHORT_IRQ | PMU.XPOWERS_AXP2101_PKEY_LONG_IRQ | # POWER KEY
|
|
# PMU.XPOWERS_AXP2101_BAT_CHG_DONE_IRQ | PMU.XPOWERS_AXP2101_BAT_CHG_START_IRQ # CHARGE
|
|
# )
|
|
|
|
PMU.enableIRQ(PMU.XPOWERS_AXP2101_BAT_NOR_UNDER_TEMP_IRQ)
|
|
# Print AXP2101 interrupt control register
|
|
PMU.printIntRegister()
|
|
|
|
PMU.enableIRQ(PMU.XPOWERS_AXP2101_PKEY_SHORT_IRQ |
|
|
PMU.XPOWERS_AXP2101_PKEY_NEGATIVE_IRQ)
|
|
# Print AXP2101 interrupt control register
|
|
PMU.printIntRegister()
|
|
|
|
PMU.enableIRQ(PMU.XPOWERS_AXP2101_BAT_OVER_VOL_IRQ)
|
|
# Print AXP2101 interrupt control register
|
|
PMU.printIntRegister()
|
|
|
|
if implementation.name == 'micropython':
|
|
irq = Pin(IRQ, Pin.IN, Pin.PULL_UP)
|
|
irq.irq(trigger=Pin.IRQ_FALLING, handler=__callback)
|
|
if implementation.name == 'circuitpython':
|
|
irq = digitalio.DigitalInOut(IRQ)
|
|
irq.switch_to_input()
|
|
|
|
while True:
|
|
if implementation.name == 'circuitpython':
|
|
if irq.value == False:
|
|
pmu_flag = True
|
|
|
|
if pmu_flag:
|
|
pmu_flag = False
|
|
# Get PMU Interrupt Status Register
|
|
status = PMU.getIrqStatus()
|
|
print("STATUS => HEX:")
|
|
print(hex(status))
|
|
|
|
if PMU.isDropWarningLevel2Irq():
|
|
print("isDropWarningLevel2")
|
|
|
|
if PMU.isDropWarningLevel1Irq():
|
|
print("isDropWarningLevel1")
|
|
|
|
if PMU.isGaugeWdtTimeoutIrq():
|
|
print("isWdtTimeout")
|
|
|
|
if PMU.isBatChargerOverTemperatureIrq():
|
|
print("isBatChargeOverTemperature")
|
|
|
|
if PMU.isBatWorkOverTemperatureIrq():
|
|
print("isBatWorkOverTemperature")
|
|
|
|
if PMU.isBatWorkUnderTemperatureIrq():
|
|
print("isBatWorkUnderTemperature")
|
|
|
|
if PMU.isVbusInsertIrq():
|
|
print("isVbusInsert")
|
|
|
|
if PMU.isVbusRemoveIrq():
|
|
print("isVbusRemove")
|
|
|
|
if PMU.isBatInsertIrq():
|
|
print("isBatInsert")
|
|
|
|
if PMU.isBatRemoveIrq():
|
|
print("isBatRemove")
|
|
|
|
if PMU.isPekeyShortPressIrq():
|
|
print("isPekeyShortPress")
|
|
|
|
if PMU.isPekeyLongPressIrq():
|
|
print("isPekeyLongPress")
|
|
|
|
if PMU.isPekeyNegativeIrq():
|
|
print("isPekeyNegative")
|
|
|
|
if PMU.isPekeyPositiveIrq():
|
|
print("isPekeyPositive")
|
|
|
|
if PMU.isWdtExpireIrq():
|
|
print("isWdtExpire")
|
|
|
|
if PMU.isLdoOverCurrentIrq():
|
|
print("isLdoOverCurrentIrq")
|
|
|
|
if PMU.isBatfetOverCurrentIrq():
|
|
print("isBatfetOverCurrentIrq")
|
|
|
|
if PMU.isBatChargeDoneIrq():
|
|
print("isBatChargeDone")
|
|
|
|
if PMU.isBatChargeStartIrq():
|
|
print("isBatChargeStart")
|
|
|
|
if PMU.isBatDieOverTemperatureIrq():
|
|
print("isBatDieOverTemperature")
|
|
|
|
if PMU.isChargeOverTimeoutIrq():
|
|
print("isChargeOverTimeout")
|
|
|
|
if PMU.isBatOverVoltageIrq():
|
|
print("isBatOverVoltage")
|
|
|
|
# Clear PMU Interrupt Status Register
|
|
PMU.clearIrqStatus()
|
|
|
|
# Print AXP2101 interrupt control register
|
|
PMU.printIntRegister()
|
|
|
|
time.sleep(0.2)
|